Comtech EF Data MBT-5000 User Manual
Page 49

MBT-5000 L-Band Up/Down Converter System
MN-MBT5000
Upgrading Firmware
Revision 4
4–3
D. On the MBT-5000 – Turn on the power.
E. Identify the Ethernet Traffic (M&C) IP Address and firmware information using one of
the following methods:
Using the MBT-5000 Serial Remote Interface (via the User PC / terminal emulator
program):
• Firmware Info – Use the <0/SWR? (condensed) or <0/FRW? (detailed) remote
query.
• Ethernet Traffic IP Address – Use the <0/IPA? remote query.
Using the MBT-5000 Front Panel menus:
• Ethernet IP Address – Use the CONFIG: Remote Ethernet Address menu
branch, as shown in this example:
Ether IP Address/Range:
192.168.001.011/24 (
◄ ►▲▼)
• Firmware Info – Use the SELECT: UTILITY Firmware Info Image#1 or
Image#2 Bulk menu branches, as shown in this example:
Bulk:FW-000303
2.1.X MM/DD/YY
Using the MBT-5000 HTTP Interface (via the User PC Web Browser – use of this
interface indicates the Ethernet Traffic IP Address is already known):
• Firmware Info – Use
the “Firmware
Information” section of
the ‘Status | Status’
page, as shown in this
example: