4 select: info (information) menu branch, 1 info: remote (remote control) – Comtech EF Data MBT-5000 User Manual
Page 72

MBT-5000 L-Band Up/Down Converter System
MN-MBT5000
Front Panel Operation
Revision 4
5–16
5.2.4
SELECT: Info (Information) Menu Branch
INFO:Remote ConvA ConvB
PSA PSB RefOsc
The Info menu branch displays read-only information on the current configuration of the unit.
Use the
◄ ► arrow keys to select from the submenu choices shown, and then press ENTER.
The submenus available from the SELECT: Info (Information) menu branch are as follows:
Submenu
Sect
Function
Remote
5.2.4.1 (Remote Control) Displays when the unit is in Local or Remote mode and gives details
of the interface type selected, etc.
ConvA
ConvB
5.2.4.2 Displays the temperature and RF power for Converter ‘A’ or Converter Unit B.
PSA
PSB
5.2.4.3 Displays the 12V, 7.8V, and 5V power supplies for Power Supply A or 12V and 5V
power supplies for Power Supply B.
RefOsc
5.2.4.4 Displays the raw voltage of the voltage tuning monitor, and the external reference
status.
5.2.4.1 INFO: Remote (Remote Control)
This screen displays when the unit is in Local or Remote mode, and gives details of the interface
type selected, etc. For example:
Remote M&C: 100BaseTx
IP Addr: 192.168.001.004
Press ENTER or CLEAR to return to the previous menu.
5.2.4.2 INFO: ConvA (Converter ‘A’) or ConvB (Converter ‘B’)
Where ‘X’ is the selected converter – Converter (Side) A or Converter (Side) B: This screen
displays the module temperature and, depending on the optional configurations:
•
For BUCs only, RF Power
•
For BDCs only, LNA Current
For example:
ConvX: Temp = +34.1 C
RF Power = +10.0 dBm
Press ENTER or CLEAR to return to the previous menu.
ConvX: Temp = +34.1 C
LNA Current = 002.3 mA