MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Front Panel Operation

Revision 4

5–15

Use the

◄ ► arrow keys to first select the digit to edit, and then use the ▼▲ arrow keys to edit

the value of that digit.

Note the following:

The valid range for this parameter is from the unit’s specific P1dB power level to P1dB minus

19 dB.

For example: For a unit with +12 dBm at P1dB, the range would be +12.0 to -7 dBm.

The default value is -20.0 dBm. Setting the parameter to this default value effectively

disables the threshold.

If Power Monitoring is not supported, and you select ConvA or ConvB, the following

message displays:

This Converter Does NOT

Support Power Monitor.

Press ENTER when done or CLEAR to return to the previous menu.