5 buc-5000x block upconverters – Comtech EF Data MBT-5000 User Manual
Page 23

MBT-5000 L-Band Up/Down Converter System
MN-MBT5000
Introduction
Revision 4
1–5
1.4.5
BUC-5000x Block Upconverters
Frequency Bands
(by Model)
Model
RF Output
IF Input
LO
BUC-5000C
5850-6425 MHz
950-1525 MHz
4900 MHz
Optional
5850-6650 MHz
950-1750 MHz
Optional
5850-6725 MHz
950-1825 MHz
BUC-5000CI (Inverted)
5850-6425 MHz
950-1525 MHz
7375 MHz
BUC-5000X
7900-8400 MHz
950-1450 MHz
6950 MHz
Optional
7900-8400 MHz
1000-1500 MHz
6900 MHz
BUC-5000Ku
13.75-14.50 GHz
950-1700 MHz
12.80 GHz
BUC-5000KuN
14.00-14.50 GHz
950-1450 MHz
13.05 GHz
BUC-5000Ka
30.00-31.00 GHz
1000-2000 MHz
29.00 GHz
Optional
27.50-28.50 GHz
950-1950 MHz
26.55 GHz
Optional
27.652-28.388 GHz
1052-1788 MHz
26.60 GHz
Optional
28.172-29.071 GHz
972-1872 MHz
27.20 GHz
Optional
28.50-29.50 GHz
950-1950 MHz
27.55 GHz
Optional
29.50-30.00 GHz
950-1450 MHz
28.55 GHz
Input/Output Impedance
50Ω
Input Return Loss
15 dB minimum
Output Return Loss
18 dB minimum
Input Connector
Type ‘N’ Female (Type ‘SMA’ for Redundancy option)
Output Connector
Type ‘N’ Female (Type ‘SMA’ for Redundancy option)
Gain
30 dB nominal at minimum attenuation
Full Band
Constant Temp – ±1.0 dB
0° to +50° C – ±0.25 dB
Per 40 MHz Slope
.03 dB/MHz maximum
Mute
-60 dBc
User Attenuation Range
0 to 20 dB, in 0.25 dB steps
Output Power, P1dB
15 dBm minimum
Noise Figure
15 dB at minimum attenuation
Intermodulation Distortion
-50 dBc at 0 dBm Total Output
Spurious (In-band)
Carrier Related
-60 dBc
Non-Carrier Related
-60 dBm
Phase Noise
Meets or exceeds MIL-STD-188-164A