beautypg.com

5 buc-5000x block upconverters – Comtech EF Data MBT-5000 User Manual

Page 23

background image

MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Introduction

Revision 4

1–5

1.4.5

BUC-5000x Block Upconverters

Frequency Bands

(by Model)

Model

RF Output

IF Input

LO

BUC-5000C

5850-6425 MHz

950-1525 MHz

4900 MHz

Optional

5850-6650 MHz

950-1750 MHz

Optional

5850-6725 MHz

950-1825 MHz

BUC-5000CI (Inverted)

5850-6425 MHz

950-1525 MHz

7375 MHz

BUC-5000X

7900-8400 MHz

950-1450 MHz

6950 MHz

Optional

7900-8400 MHz

1000-1500 MHz

6900 MHz

BUC-5000Ku

13.75-14.50 GHz

950-1700 MHz

12.80 GHz

BUC-5000KuN

14.00-14.50 GHz

950-1450 MHz

13.05 GHz

BUC-5000Ka

30.00-31.00 GHz

1000-2000 MHz

29.00 GHz

Optional

27.50-28.50 GHz

950-1950 MHz

26.55 GHz

Optional

27.652-28.388 GHz

1052-1788 MHz

26.60 GHz

Optional

28.172-29.071 GHz

972-1872 MHz

27.20 GHz

Optional

28.50-29.50 GHz

950-1950 MHz

27.55 GHz

Optional

29.50-30.00 GHz

950-1450 MHz

28.55 GHz

Input/Output Impedance

50Ω

Input Return Loss

15 dB minimum

Output Return Loss

18 dB minimum

Input Connector

Type ‘N’ Female (Type ‘SMA’ for Redundancy option)

Output Connector

Type ‘N’ Female (Type ‘SMA’ for Redundancy option)

Gain

30 dB nominal at minimum attenuation

Full Band

Constant Temp – ±1.0 dB
0° to +50° C – ±0.25 dB

Per 40 MHz Slope

.03 dB/MHz maximum

Mute

-60 dBc

User Attenuation Range

0 to 20 dB, in 0.25 dB steps

Output Power, P1dB

15 dBm minimum

Noise Figure

15 dB at minimum attenuation

Intermodulation Distortion

-50 dBc at 0 dBm Total Output

Spurious (In-band)

Carrier Related

-60 dBc

Non-Carrier Related

-60 dBm

Phase Noise

Meets or exceeds MIL-STD-188-164A