beautypg.com

4 summary of specifications, 1 physical & environmental, 2 prime power – Comtech EF Data MBT-5000 User Manual

Page 22: 3 monitor & control, 4 reference

background image

MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Introduction

Revision 4

1–4

1.4

Summary of Specifications

1.4.1

Physical & Environmental

Weight

15 lbs. (6.80 kg) Nominal

Dimensions (excluding connectors)

See Figure 1-3

Temperature

Operating

32º to 132.8ºF (0º to 56ºC)

Non-operating (Storage) -58º to 158ºF (-50º to 70ºC)

Operational Altitude

15,000 ft above sea level

Shock

Normal commercial shipping and handling

1.4.2

Prime Power

Voltage

90 – 260 VAC, -48 VDC Optional

Frequency

47 to 63 Hz

Dissipation

60 Watts, typical

1.4.3

Monitor & Control

Serial M&C Interface

TIA/EIA-232, TIA/EIA-485, 4-wire

DB-9F

Alarm

Form C, DB-9F

Redundant Switch Connections

SMA Female

Remote Interface

RJ-45 Ethernet

1.4.4

Reference

External Input

5 or 10 MHz 0 ±5 dBm optional

BNC Female

Output

10 MHz Rear Panel

BNC Female

Internal

Stability over Time

±

1x10

-9

/Day

Stability over Temp

±

1x10

-8

/Day