MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Serial-based Remote Product Management

Revision 4

7–16

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes between 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to query

(Target to

Controller)

Retrieve Next 5

unread stored

Events

N/A

75 bytes

Query only.

Unit returns the oldest 5 Stored Events which have not yet been read over the remote control.

Reply format: {CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body, where

Sub-body= ABCddmmyyhhmmss:

A being the fault/clear indicator.

F = Fault

C = Clear

I = Info

B being the fault type where:

1 = Base Unit

2 = Converter A

3 = Converter B

C is Fault Code numbers, where

For the base unit,

0 = No faults

1 = +12V Power Supply 1

2 = +12V Power Supply 2

3 = +5V Power Supply 1

4 = +5V Power Supply 2

5 = +7.8V Power Supply

6 = Flash Checksum

7 = FPGA Done

8 = External Ref Lock Detect

9 = Converter A1 Not Inserted

A = Converter B2 Not Inserted

B = Switch Fault

H = Power On

I = Power Off

J = Log Clear

K = Redundancy Config Change

For the Converter A and B,

1 = Synthesizer Lock Detect

2 = Heat-sink Temperature

3 = Low Forward RF Power

4 = LNA Current Supply

5 = High Temperature (Alarm)

If there are less than 5 events to be retrieved, the remaining positions are padded with zeros. If

there are no new events, the response is RNE*.

N/A

RNE?

RNE={CR}ABCddmm

yyhhmmss{CR}ABCd

dmmyyhhmmss{CR}A

BCddmmyyhhmmss{

CR}ABCddmmyyhhm

mss{CR}ABCddmmyy

hhmmss

(See Description of

Arguments)