Comtech EF Data MBT-5000 User Manual
Page 118

MBT-5000 L-Band Up/Down Converter System
MN-MBT5000
Serial-based Remote Product Management
Revision 4
7–16
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
Retrieve Next 5
unread stored
Events
N/A
75 bytes
Query only.
Unit returns the oldest 5 Stored Events which have not yet been read over the remote control.
Reply format: {CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body, where
Sub-body= ABCddmmyyhhmmss:
A being the fault/clear indicator.
F = Fault
C = Clear
I = Info
B being the fault type where:
1 = Base Unit
2 = Converter A
3 = Converter B
C is Fault Code numbers, where
For the base unit,
0 = No faults
1 = +12V Power Supply 1
2 = +12V Power Supply 2
3 = +5V Power Supply 1
4 = +5V Power Supply 2
5 = +7.8V Power Supply
6 = Flash Checksum
7 = FPGA Done
8 = External Ref Lock Detect
9 = Converter A1 Not Inserted
A = Converter B2 Not Inserted
B = Switch Fault
H = Power On
I = Power Off
J = Log Clear
K = Redundancy Config Change
For the Converter A and B,
1 = Synthesizer Lock Detect
2 = Heat-sink Temperature
3 = Low Forward RF Power
4 = LNA Current Supply
5 = High Temperature (Alarm)
If there are less than 5 events to be retrieved, the remaining positions are padded with zeros. If
there are no new events, the response is RNE*.
N/A
RNE?
RNE={CR}ABCddmm
yyhhmmss{CR}ABCd
dmmyyhhmmss{CR}A
BCddmmyyhhmmss{
CR}ABCddmmyyhhm
mss{CR}ABCddmmyy
hhmmss
(See Description of
Arguments)