beautypg.com

3 features, 1 block upconverter (buc-5000x), 2 block downcoverter (bdc-5000x) – Comtech EF Data MBT-5000 User Manual

Page 21

background image

MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Introduction

Revision 4

1–3

1.3

Features

Meets or exceeds IESS-308/309

Low phase noise

20 dB gain adjustment

Flexible configuration

RF Band switching in minimal time without requiring tools

Optional 1:1 Redundancy

1.3.1

Block Upconverter (BUC-5000x)

The BUC-5000x field interchangeable upconverter module translates an L-Band input carrier to the

desired output frequency (C-Band, X-Band, or Ku-Band) with an output level capable of driving a

high-powered amplifier (HPA).

Note the following:

C-Band

5850 to 6425 MHz (Invert optional)

X-Band

7900 to 8400 MHz

Ku-Band

13.75 to 14.50 GHz

1.3.2

Block Downcoverter (BDC-5000x)

The BDC-5000x field-interchangeable downconverter module translates a band-specific input

frequency block (C-Band, X-Band, or Ku-Band) from the LNA down to L-Band (950 to 2000 MHz).

Note the following:

C-Band

3400 to 4200 MHz (Non-Invert optional)

X-Band

7250 to 7750 MHz

Ku-Band

10.95 to 12.75 GHz