2 config: fltrec (fault recovery) menu – Comtech EF Data MBT-5000 User Manual
Page 65

MBT-5000 L-Band Up/Down Converter System
MN-MBT5000
Front Panel Operation
Revision 4
5–9
SNMP: Traps
SNMP Trap IP Address:
IP1 IP2 Version
Use the
◄ ► arrow keys to select IP1, IP2, or Version, and then press ENTER.
SNMP Trap IP Address: IP1 or IP2
Trap IP #1:
000.000.000.000(◄ ► ▲ ▼ E)
Trap IP #2:
000.000.000.000(◄ ► ▲ ▼ E)
To edit the Trap Destination IP Addresses: First, use the
◄ ► arrow keys to select the
digit to edit, and then use the
▼▲ arrow keys to edit the value of that digit. Press
ENTER when done.
If both Trap IP Addresses are 000.000.000.000, it means Traps are
disabled
.
SNMP Trap IP Address: Version
Trap Version:
SNMPv1 SNMPv2 (◄ ► E)
Use the
◄ ► arrow keys to select the trap version – SNMPv1 or SNMPv2 – and then
press ENTER.
5.2.2.2 CONFIG: FltRec (Fault Recovery) Menu
Fault Recovery: Manual
Automatic (◄ ► E)
Use the
◄ ► arrow keys to select Manual or Automatic, and then press ENTER.
5.2.2.3 CONFIG: ConvA or ConvB (Converter ‘A’ or Converter ‘B’) Menus
Converter X
Mute/Freq Attenuation
Where ‘X’ is the selected converter – Converter (Side) A or Converter (Side) B – use the arrow
keys to select Mute/Freq or Attenuation, and then press ENTER.