MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Serial-based Remote Product Management

Revision 4

7–22

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of arguments

(Note that all arguments are ASCII numeric codes between 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to query

(Target to

Controller)

Part Number

N/A

Various 1-96

bytes

Query only.

Returns the Comtech EF Data part number of the unit. This part number is the unit’s DOTCODE

at the time it was manufactured. The DOTCODE may be up to 96 printable ASCII characters

long.

Example: <2/PNM?’cr’

>0002/PNM=BUCC0.350WRSW00’cr’’lf’

N/A

PNM?

PNM=x….x

(See Description of

Arguments)

Redundancy

Online Status

RED=

1 byte

Command or Query.

Forces the unit to throw the switches, causing the unit to go offline (if it is currently online). The

unit cannot be forced online, and sending a 1 will have no effect.

0 = Offline

1 = Online (query only)

Default value: 0

Example: <2/RED=0’cr’

>0002/RED=’cr’’lf’

RED=

RED?

RED*

RED?

RED=x

Retrieve

Equipment Type

N/A

53 bytes

(includes ‘cr’)

Query only.

Used to Query the block converter type and its start and stop frequencies.

Example:

<2/RET?’cr’

>0002/RET=5000 C-Band BUC’cr’

05850-06425’cr’

xxxxx-xxxxx’cr’

xxxxx-xxxxx’cr’’lf’

Example for a tri-band converter:

<2/RET?’cr’

>0002/RET=5000 Ku-Band BDC’cr’

10950-11700’cr’

11700-12250’cr’

12250-12750’cr’’lf’

N/A

RET?

RET=x….x

(see description for

details of arguments)

Retrieve

Maintenance

Status

N/A

Variable length

Query only.

Queries the Maintenance status of the unit.

RMS?

RMS=x….x

(See Description of

Arguments)

Example

Description

<2/RMS?’cr’

>0002/RMS=’cr’

SYNVT=001.2’cr’

HSTMP=+12.3’cr’

LNACS=380.2’cr’

FWPWR=004.9’cr’lf’

Synthesizer Voltage

Temperature

LNA Current Supply (in mA)

Forward Power