Comtech EF Data MBT-5000 User Manual
Page 120

MBT-5000 L-Band Up/Down Converter System
MN-MBT5000
Serial-based Remote Product Management
Revision 4
7–18
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numeric codes between 48 and 57)
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
Set RTC Time
TIM=
6 bytes
Command or Query.
Indicates the time from midnight, in the form hhmmss, where:
hh = hours, between 00 and 23;
mm=minutes between 00 and 59, and
ss= seconds between 00 and 59.
Example: <1/TIM=231259’cr’
>0001/TIM=’cr’’lf’
(time = 23 hours, 12 minutes and 59 seconds since midnight)
TIM =
TIM?
TIM *
TIM?
TIM=xxxxxx
(Same format as
Command
arguments)
Time Protocol
Enable
TPE=
1 byte
Command or Query.
Used to enable or disable the Time Protocol, where:
0 = Time protocol disabled
1 = Time protocol enabled
Example: TPE=1 (Time protocol enabled)
TPE =
TPE?
TPE?
TPE=x
(See Description of
Arguments)
Time Protocol
Server
TPS=
15 bytes
Command or Query.
Used to set the Time Server IP address for the Unit Tx Ethernet management port, in the format:
xxx.xxx.xxx.xxx, where:
xxx.xxx.xxx.xxx is the Time server IP address
Example: TPS=192.168.001.005
TPS=
TPS?
TPS?
TPS=
xx.xxx.xxx.xxx.yy
(See Description of