beautypg.com

1 optional -48v dc operation – apply power – Comtech EF Data MBT-5000 User Manual

Page 45

background image

MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Rear Panel Connections

Revision 4

3–13

3.3.3

Optional -48V Direct Current (DC) Power Interface

Figure 3-9. MBT-5000 Optional DC Power Interface

3.3.3.1 Optional -48V DC Operation – Apply Power

Figure 3-10. Apply DC Power to the MBT-5000

To apply DC power to the MBT-5000, do these steps:

First, connect the user-supplied (+) and (–) DC power leads to their respective terminals.

Number 18 AWG minimum wires are recommended.

Then, connect the user-supplied DC power leads to the power source.

Finally, switch the unit ON.

Feature

Description

1

Power Terminal Block

2

On / Off Switch

3

Fuse Holder

DC Power Specifications

Input Power

75W maximum, less than 65W typical

Input Voltage

36 to 72 VDC

Connector Type

Terminal Block

Fuse Protection

(1X) 3.15A 5 x 20mm slow-blow fuse