beautypg.com

Comtech EF Data MBT-5000 User Manual

Page 112

background image

MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Serial-based Remote Product Management

Revision 4

7–10

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes between 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to query

(Target to

Controller)

Enable

Statistics

Averaging

ESA=

1 byte

Command or Query.

Enables or D isables averaging of statistics data at a r ate of once per second for 10 s econd. If

disabled, burst values will be logged instead of averaged values.

0 = Disabled

1 = Enabled

Default Value: 0

Example: <1/ESA=0’cr’

>0001/ESA=’cr’’lf’

ESA=

ESA?

ESA?

ESA=x

(Same format as

Command

arguments)

Enable

Statistics

Logging

ESL=

1 byte

Command or Query.

Enables or Disables the statistics logging function.

0 = Disable

1 = Enable

Default Value: 0

Example: <1/ESL=1’cr’

>0001/ESL=’cr’’lf’

ESL=

ESL?

ESL?

ESL=x

(Same format as

Command

arguments)

Enable

Redundancy

Switch Mode

ESW=

1 byte

Command or Query.

Turns ON or OFF the redundancy state, where:

0 = Off

1 = On

Default value: 1

Example: <1/ESW=1’cr’

>0001/ESW=’cr’’lf’

ESW=

ESW?

ESW *

ESW?

ESW=x

Retrieve

Firmware

Number

N/A

variable length

Query only.

Returns the firmware type loaded into the unit.

i = Bulk Image Number (1 or 2)

a = Firmware Image

b = Firmware Revision

c = Firmware Date

N/A

FRW?i

FRW={CR}Boot:{CR}

abc{CR}Bulki:{CR}abc

{CR}abc

(See Description of

Arguments)