Comtech EF Data MBT-5000 User Manual

Page 119

background image

MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Serial-based Remote Product Management

Revision 4

7–17

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes between 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to query

(Target to

Controller)

Remote Baud

Rate

SBR=

4 bytes

Command or Query.

Set remote baud rate as follows:

2400 = 2400 baud

4800 = 4800 baud

9600 = 9600 baud

19K2 = 19200 baud

38K4 = 38400 baud

Default Value: 9600

Example: <1/SBR=9600’cr’

>0001/SBR=9600’cr’’lf’

Note: When changing baud rates remotely the response to the command will be returned using

the same baud rate as that used to send the command.

SBR=

SBR?

SBR?

SBR=xxxx

(See format as

Command

arguments)

Serial Number

N/A

9 bytes

Query only.

Queries the unit 9-digit serial number. Unit returns its S/N in the form xxxxxxxxx.

Example: SNO=176500143

N/A

SNO?

SNO=xxxxxxxxx

(See Description of

Arguments)

Remote

Address

SPA=

4 bytes

Command or Query.

Sets Physical Address - between 0001 to 9997. Resolution = 0001.

Example: <1/SPA=0412’cr’

>0001/SPA=’cr’’lf’

Default Value: 0001

Note: 9998 and 9999 are reserved for the block converter A and B if the base address is 9997.

SPA=

SPA?

SPA?

SPA=xxxx

(Same format as

Command

arguments)

Set Statistics

Interval

SSI=

2 bytes

Command or Query.

Sets interval at which statistics are logged. Minimum resolution is 10 m inutes, maximum is 90

minutes in 10 minute intervals.

Default Value: 90

Example: <1/SSI=90’cr’

>0001/SSI=’cr’’lf’

SSI=

SSI?

SSI?

SSI=xx

(Same format as

Command

arguments)

Software

Revision

N/A

variable length

Query only.

Unit returns the value of the internal software revision installed in the unit, in the form :

Boot:x.y.z Bulk1:x.y.z Bulk2:x.y.z

-or-

Boot:x.y.zz Bulk1:x.y.zz Bulk2:x.y.zz

N/A

SWR?

SWR=Boot:x.y.zz

Bulk1:x.y.zz

Bulk2:x.y.zz

(See Description

of Arguments)