MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Serial-based Remote Product Management

Revision 4

7–13

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

(Note that all arguments are ASCII numeric codes between 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to query

(Target to

Controller)

Power Supply

Alarm Mask

MPS=

2 bytes

Command or Query

Sets or returns Power Supply Alarm mask conditions in the form ab, where:

0 = Fault, 1 = Alarm, 2 = Masked

a = Power Supply 1

b = Power Supply 2

Default value: 12

If MPS=00 and any of the voltages on either supply are out of range, then both front panel

“SUM FAULT” LEDs are lit, the summary fault relay is put in the "faulted" position, it is a logged

event, and no switchover occurs.

If MPS=11 and any of the voltages on either supply are out of range, then both front panel “SUM

FAULT” LEDs are lit, the summary fault relay is not affected, it is a logged event, and no

switchover occurs.

If MPS=22 and any of the voltages on either supply are out of range, then both front panel “SUM

FAULT” LEDs are NOT lit (because of the power supply), the summary fault relay is NOT

affected, it is NOT a logged event, and no switchover occurs.

If BOTH power supplies are faulted, then a fault is reported even if they are masked.

MPS=

MPS?

MPS*

MPS?

MPS=ab

(see description for

details of arguments)

Unit Alarm Mask MSK=

5 bytes

Command or Query.

Alarm mask conditions. If an alarm is masked, neither an alarm or a fault is set, and the user will not

know of a problem, in the form abcde, where:

0 = Fault, 1 = Alarm, 2 = Masked

a = Low Forward RF Power

b = External Reference Lock detect

c = Converter A Not Inserted

d = Converter B Not Inserted

e = LNA Current Detect

Default value: 22111

Note: There could be a variable delay in the time it takes for the internal reference to lock to an

external reference, due to warm-up characteristics and frequency differences between the

references. Therefore, the default setting is "masked" for the reference lock detect. This setting

may be changed if the customer so desires. The delay should be less than 1 second after 30

minutes of warm-up time.

MSK=

MSK?

MSK*

MSK?

MSK=abcde

(See Description of

Arguments)

Number of

Unread stored

Events

N/A

3 bytes

Query only.

Unit returns the Number of stored Eventsthat remain Unread in the form xxx.

Example: NUE=126

N/A

NUE?

NUE=xxx