6 bdc-5000x block downconverters – Comtech EF Data MBT-5000 User Manual
Page 24

MBT-5000 L-Band Up/Down Converter System
MN-MBT5000
Introduction
Revision 4
1–6
1.4.6
BDC-5000x Block Downconverters
Frequency Bands
(by Model)
Model
RF Output
IF Input
LO
BDC-5000C
3400-4200 MHz
950-1750 MHz
5150 MHz
BDC-5000CNI
(Non-Inverting
3625-4200 MHz
1325-1900 MHz
2300 MHz
BDC-5000X
7250-7750 MHz
950-1450 MHz
6300 MHz
Optional
7250-7750 MHz
1000-1500 MHz
6250 MHz
BDC-5000K (Standard)
10.95-11.70 GHz
950-1700 MHz
10.00 GHz
Switched LO
11.70-12.20 GHz
950-1450 MHz
10.75 GHz
12.25-12.75 GHz
950-1450 MHz
11.30 GHz
OPTION 1
10.95-11.70 GHz
950-1700 MHz
10.00 GHz
11.70-12.75 GHz
950-2000 MHz
10.75 GHz
OPTION 2
10.70-11.70 GHz
950-1950 MHz
9.75 GHz
11.70-12.75 GHz
950-2000 MHz
10.75 GHz
BDC-5000Ka
20.20-21.20 GHz
950-1950 MHz
19.25 GHz
Optional
17.70-18.70 GHz
950-1950 MHz
16.75 GHz
Optional 17.852-18.588 GHz
1052-1788 MHz
16.80 GHz
Optional 18.372-19.271 GHz
972-1871 MHz
17.40 GHz
Optional
18.70-19.20 GHz
950-1450 MHz
17.75 GHz
Optional
19.20-20.20 GHz
950-1950 MHz
18.25 GHz
Input/Output Impedance
50Ω
Input Return Loss
18 dB minimum
Output Return Loss
15 dB minimum
Input Connector
Type ‘N’ Female (Type ‘SMA. for Redundancy option)
Output Connector
Type ‘N’ Female (Type ‘SMA’ for Redundancy option)
Gain
35 dB nominal at minimum attenuation
Full Band
Contant Temp – ±0.25 dB
0° to +50° C – ±1.0 dB
Per 40 MHz Slope
.03 dB/MHz maximum
Mute
-60 dBc
User Attenuation Range
0 to 20 dB, in 0.25 dB steps
Output Power, P1dB
15 dBm minimum
Noise Figure
15 dB at minimum attenuation
Intermodulation Distortion
-50 dBc at 0 dBm Total Output
Spurious (In-band)
Carrier Related
-60 dBc
Non-Carrier Related
-60 dBm
Phase Noise
Meets or exceeds MIL-STD-188-164A