beautypg.com

6 bdc-5000x block downconverters – Comtech EF Data MBT-5000 User Manual

Page 24

background image

MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Introduction

Revision 4

1–6

1.4.6

BDC-5000x Block Downconverters

Frequency Bands

(by Model)

Model

RF Output

IF Input

LO

BDC-5000C

3400-4200 MHz

950-1750 MHz

5150 MHz

BDC-5000CNI

(Non-Inverting

3625-4200 MHz

1325-1900 MHz

2300 MHz

BDC-5000X

7250-7750 MHz

950-1450 MHz

6300 MHz

Optional

7250-7750 MHz

1000-1500 MHz

6250 MHz

BDC-5000K (Standard)

10.95-11.70 GHz

950-1700 MHz

10.00 GHz

Switched LO

11.70-12.20 GHz

950-1450 MHz

10.75 GHz

12.25-12.75 GHz

950-1450 MHz

11.30 GHz

OPTION 1

10.95-11.70 GHz

950-1700 MHz

10.00 GHz

11.70-12.75 GHz

950-2000 MHz

10.75 GHz

OPTION 2

10.70-11.70 GHz

950-1950 MHz

9.75 GHz

11.70-12.75 GHz

950-2000 MHz

10.75 GHz

BDC-5000Ka

20.20-21.20 GHz

950-1950 MHz

19.25 GHz

Optional

17.70-18.70 GHz

950-1950 MHz

16.75 GHz

Optional 17.852-18.588 GHz

1052-1788 MHz

16.80 GHz

Optional 18.372-19.271 GHz

972-1871 MHz

17.40 GHz

Optional

18.70-19.20 GHz

950-1450 MHz

17.75 GHz

Optional

19.20-20.20 GHz

950-1950 MHz

18.25 GHz

Input/Output Impedance

50Ω

Input Return Loss

18 dB minimum

Output Return Loss

15 dB minimum

Input Connector

Type ‘N’ Female (Type ‘SMA. for Redundancy option)

Output Connector

Type ‘N’ Female (Type ‘SMA’ for Redundancy option)

Gain

35 dB nominal at minimum attenuation

Full Band

Contant Temp – ±0.25 dB
0° to +50° C – ±1.0 dB

Per 40 MHz Slope

.03 dB/MHz maximum

Mute

-60 dBc

User Attenuation Range

0 to 20 dB, in 0.25 dB steps

Output Power, P1dB

15 dBm minimum

Noise Figure

15 dB at minimum attenuation

Intermodulation Distortion

-50 dBc at 0 dBm Total Output

Spurious (In-band)

Carrier Related

-60 dBc

Non-Carrier Related

-60 dBm

Phase Noise

Meets or exceeds MIL-STD-188-164A