MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Ethernet-based Remote Product Management

Revision 4

6–4

Type the SNMP Community String into the user-supplied MIB Browser or Network Node

Management software. You must define three Community Strings for SNMP access:

• Read Community default = public

• Write Community default = private

• Trap Community default = comtech

For proper SNMP operation, the MBT-5000 MIB files must be used with the

associated version of the MBT-5000 Remote Router M&C. Refer to the MBT-5000

Firmware Release Notes for information on the required FW/SW compatibility.

6.3.3 SNMP Traps

The MBT-5000 supports both SNMPv1 traps and SNMPv2 notifications. The MBT-5000 has the

ability to send out SNMP traps when certain events occur in the unit. A trap is sent both when a

fault occurs and is cleared. You may configure which style of traps the MBT-5000 sends by using

the MBT-5000SNMPTrapVersion OID.

The following MIB2 SNMPv1traps and SNMPv2 notifications are supported by the MBT-5000:

MIB2 SNMPv1 trap: Authentication Failure

5

MIB2 SNMPv2 notifications: Authentication Failure

1.3.6.1.6.3.1.1.5.5

The following Faults SNMPv1 traps and SNMPv2 notifications are supported by the MBT-5000.

Faults SNMPv1 traps:

mbt5000BaseUnitFaultV1

6247501

mbt5000ConvAFaultV1

6247502

mbt5000ConvBFaultV1

6247503

Faults SNMPv2 notifications:

mbt5000BaseUnitFaultEvent

1.3.6.1.4.1.6247.50.2.1.1

mbt5000ConvAFaultEvent

1.3.6.1.4.1.6247.50.2.1.2

mbt5000ConvBFaultEvent

1.3.6.1.4.1.6247.50.2.1.3