MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Serial-based Remote Product Management

Revision 4

7–19

7.3.2

Block Converter (BUC / BDC) Remote Commands and Queries

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of arguments

(Note that all arguments are ASCII numeric codes between 48 and 57)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to query

(Target to

Controller)

Attenuation

Offset

AOF=

5 bytes

Command or Query.

Note: Command is only for the offline converter in a redundancy mode. The valid range is -3.00 to

+3.00 dB.

Additionally, if the online converter attenuation is set to one extreme or the other, that value

becomes the new limiting factor. For example, if the attenuation is set to 19dB, the only

allowable offset will be -3 dB to +1 dB.

Default Value: 00.00

Example: <2/AOF=+2.25’cr’

>0002/AOF=’cr’’lf’

AOF=

AOF?

AOF*

AOF?

AOF=+x.xx

or

AOF=-x.xx

(Same format as

Command

arguments)

Attenuation

ATT=

5 bytes,

Command or Query.

Valid attenuation level (00.00 to 50.00 for X-Band BUC units, 00.00 to 20.00 for all other), in dB,

in 0.25 dB steps as factory default.

Default Value: 00.00

Example: <2/ATT=12.25’cr’

>0002/ATT=’cr’’lf’

Note: Attenuation cannot be changed for the offline unit when in redundancy mode.

ATT=

ATT?

ATT*

ATT?

ATT=xx.xx

(Same format as

Command

arguments)

Calibrate LNA

Current

(BDC only)

CLC=

none

Command or Query.

Stores t he v alue of t he LN A C urrent S upply (i n m A) as a ref erence p oint. The LN A c urrent

alarm/fault point is then based on this point  the LCW setting.

Note: This command will return a mode error if the LCS output has not been enabled first. It will

return 000.0 if the converter has never been calibrated.

Example: <1/CLC=’cr’

>0001/CLC=’cr’’lf’

The CLC query will return the value that was stored during the LNA current calibration.

Example: <1/CLC?’cr’

>0001/CLC=xxx.x

(where xxx.x is calibrated LNA current value in mA)

CLC=

CLC?

CLC*

CLC?

CLC=xxx.x

(see Description

of Arguments)