MBT-5000 L-Band Up/Down Converter System

MN-MBT5000

Front Panel Operation

Revision 4

5–6

5.2.2

SELECT: Config (Configuration) Menu Branches

CONFIG: Remote FltRec

ConvA ConvB RefAdj Redun

Use the

◄ ► arrow keys to select from the submenu choices shown, and then press ENTER.

The submenus available from the SELECT: Config (Configuration) menu branch are as follows:

Submenu

Sect

Function

Remote

5.2.2.1 (Remote Control) Used to define whether you control the unit locally or remotely, and

identifies the unit address, interface type, and rate and format of the baud parameters.

FltRec

5.2.2.2 (Fault Recovery) Used to configure Fault Recovery (AFR) in Auto or Manual mode.

ConvA

ConvB

5.2.2.3 (Converter ‘A’ or ‘B’) Displays the current configuration of the selected converter,

including the frequency, attenuation, and slope.

RefAdj

5.2.2.4 (Reference Oscillator Adjustment) Used to adjust the reference oscillator.

Redun

5.2.2.5 (Redundancy) Used to identify the redundancy state and mode (see Appendix B.

MBT-5000 REDUNDANCY OPERATION for further information).

5.2.2.1 CONFIG: Remote (Remote Control) Menus

Remote Control: Local

Serial Ethernet (◄ ► E)

Use the

◄ ► arrow keys to select Local, Serial, or Ethernet, and then press ENTER.

5.2.2.1.1

Remote Control: Local

When you select Local mode, this disables remote control, although remote monitoring is still

possible.

5.2.2.1.2

Remote Control: Serial

Serial Config: Interface

Address Baudrate

Use the

◄ ► arrow keys to select Interface, Address, or Baudrate, and then press ENTER.

Serial Config: Interface

M&C Bus Interface: RS232

RS485-2W RS485-4W (◄ ► E)

Use the

◄ ► arrow keys to select RS232, RS485-2W (2-wire), or RS485-4W (4-wire), and

then press ENTER.