Page 62: 2 remote control: serial

MBT-5000 L-Band Up/Down Converter System
MN-MBT5000
Front Panel Operation
Revision 4
5–6
5.2.2
SELECT: Config (Configuration) Menu Branches
CONFIG: Remote FltRec
ConvA ConvB RefAdj Redun
Use the
◄ ► arrow keys to select from the submenu choices shown, and then press ENTER.
The submenus available from the SELECT: Config (Configuration) menu branch are as follows:
Submenu
Sect
Function
Remote
5.2.2.1 (Remote Control) Used to define whether you control the unit locally or remotely, and
identifies the unit address, interface type, and rate and format of the baud parameters.
FltRec
5.2.2.2 (Fault Recovery) Used to configure Fault Recovery (AFR) in Auto or Manual mode.
ConvA
ConvB
5.2.2.3 (Converter ‘A’ or ‘B’) Displays the current configuration of the selected converter,
including the frequency, attenuation, and slope.
RefAdj
5.2.2.4 (Reference Oscillator Adjustment) Used to adjust the reference oscillator.
Redun
5.2.2.5 (Redundancy) Used to identify the redundancy state and mode (see Appendix B.
MBT-5000 REDUNDANCY OPERATION for further information).
5.2.2.1 CONFIG: Remote (Remote Control) Menus
Remote Control: Local
Serial Ethernet (◄ ► E)
Use the
◄ ► arrow keys to select Local, Serial, or Ethernet, and then press ENTER.
5.2.2.1.1
Remote Control: Local
When you select Local mode, this disables remote control, although remote monitoring is still
possible.
5.2.2.1.2
Remote Control: Serial
Serial Config: Interface
Address Baudrate
Use the
◄ ► arrow keys to select Interface, Address, or Baudrate, and then press ENTER.
Serial Config: Interface
M&C Bus Interface: RS232
RS485-2W RS485-4W (◄ ► E)
Use the
◄ ► arrow keys to select RS232, RS485-2W (2-wire), or RS485-4W (4-wire), and
then press ENTER.