beautypg.com

Main menu, Options, Main menu 4.3.1. options – Dataman 520 Series User Manual

Page 51

background image


DATAMAN oscilloscope

User’s Guide

4.3. Main menu

The main menu is located at the top of the main window. The following menu items
are available:

File | Print – Opens print manager.

File | Exit – Closes application.

View | Simple mode – Activates simple mode of the main window.

View | Classic mode – Activates classic mode of the main window.

Edit | Export as ASCII | Manage exports – Opens the window, where the

export definitions can be configured. Click item in the File | Export as ASCII to
export data using specified definition.

Edit | Export as image | Manage exports – Opens the window, where the

export definitions can be configured. Click item in the File | Export as image to
export data using specified definition.

Settings | Save settings – Saves current settings into the selected file

Settings | Load settings – Loads settings from the selected file

Settings | Reset to factory defaults – Restores factory default

Settings | Process licence file – Loads and processes the specified licence file

Settings | External trigger output | Compensation generator –

Activates/deactivates compensation generator.

Settings | WCD sensitivity | Very high – Sets very high WCD sensitivity.

Settings | WCD sensitivity | High – Sets high WCD sensitivity

Settings | WCD sensitivity | Medium – Sets medium WCD sensitivity

Settings | WCD sensitivity | Low – Sets low WCD sensitivity

Settings | WCD sensitivity | Off – Turns the WCD off

Settings | Digital shielding level – Opens window, where you can select the

digital shielding level.

Settings | Options – Opens the window where the software options can be

changed

Tools | Mask test | Create mask – Opens the window where you can select the

mask parameters

Tools | Mask test | Load mask – Loads the mask from selected file

Tools | Vertical shift calibration | Calibrate vertical shift – Opens the wizard

which will guide you through the calibration process

Tools | Vertical shift calibration | Calibration data | Use calibration data – In

case the additional calibration data is loaded, this item is checked. Click it to turn
using this data off. Turning them off is not permanent – once the application is
restarted the data will be loaded.

Tools | Vertical shift calibration | Calibration data | Delete calibration data

Click this item to delete calibration data saved on the disk. The calibration data in the
device remains intact.

Help | Help – Displays the Help index
Help | View readme – Opens the readme.txt file, which contains information
about implemented changes in the application
Help | About – Displays information about the product.

4.3.1. Options

Click the item in the main menu to open the options window.

- 51 -

This manual is related to the following products: