beautypg.com

D-Link DES-3018 User Manual

Page 206

background image

DES-3010F/DES-3010FL/DES-3010G/DES-3016/DES-3018/DES-3026 Fast Ethernet Switch Manual

193

Figure 11- 27. Authenticator Statistics window

The user may select the desired time interval to update the statistics, between 1s and 60s, where “s” stands
for seconds. The default value is one second.
The following fields can be viewed:

Parameter Description

Port

The identification number assigned to the Port by the System in which the Port resides.

Frames Rx

The number of valid EAPOL frames that have been received by this Authenticator.

Frames Tx

The number of EAPOL frames that have been transmitted by this Authenticator.

Rx Start

The number of EAPOL Start frames that have been received by this Authenticator.

TxReqId

The number of EAP Req/Id frames that have been transmitted by this Authenticator.

RxLogOff

The number of EAPOL Logoff frames that have been received by this Authenticator.

Tx Req

The number of EAP Request frames (other than Rq/Id frames) that have been transmitted by
this Authenticator.

Rx RespId

The number of EAP Resp/Id frames that have been received by this Authenticator.

Rx Resp

The number of valid EAP Response frames (other than Resp/Id frames) that have been
received by this Authenticator.