Appendix, Cabinet size 1, 2 or 3 by model and model size, Cross-referenced to heat section size and type – Reznor YDSA Unit Installation Manual User Manual

Page 68: Wiring diagram option identification

background image

Form I-Y, P/N 273646R6, Page 68

Appendix

Cabinet Size 1, 2 or 3 by Model and Model Size Cross-Referenced to Heat Section

Size and Type

Model

YDHA

YDMA

YDSA

Size 60 90 120 150 180 210 240 300 360 60 90 120 150 180 210 240 300 360 120 150 180 210

Nominal Cooling

Capacity (Tons) 5 7.5 10 12.5 15 17.5 20 25 30 5 7.5 10 12.5 15 17.5 20 25 30 10 12.5 15 17.5

Standard

Efficiency

Gas Heat

Section

Opt

Code

Opt

Code

H50

1

1

1

--

--

--

--

--

--

1

--

--

--

--

--

--

--

--

--

--

--

--

H50

H75

1

1

1

1

2

--

--

--

--

1

1

1

--

--

--

--

--

--

--

--

--

--

H75

H100

1

1

1

1

2

2

2

--

--

1

1

1

1

--

--

--

--

--

2

--

--

-- H100

H102*

1

1

1

1

2

2

2

--

--

1

1

1

1

--

--

--

--

--

2

--

--

-- H102*

H125*

1

1

1

1

2

2

2

--

--

1

1

1

1

2

--

--

--

--

2

2

--

-- H125*

H150*

1

1

1

1

2

2

2

--

--

1

1

1

1

2

2

--

--

--

2

2

3

-- H150*

H175*

1

1

1

1

2

2

2

--

--

1

1

1

1

2

2

2

--

--

2

2

3

3 H175*

H200

--

1

1

1

2

2

2

3

3

1

1

1

1

2

2

2

3

3

2

2

3

3

H200

H202*

--

1

1

1

2

2

2

3

3

1

1

1

1

2

2

2

3

3

2

2

3

3 H202*

H300

--

1

1

1

2

2

2

3

3

--

1

1

1

2

2

2

3

3

2

2

3

3

H300

H400

--

--

1

1

2

2

2

3

3

--

--

1

1

2

2

2

3

3

2

2

3

3

H400

H402*

--

--

1

1

2

2

2

3

3

--

--

1

1

2

2

2

3

3

2

2

3

3 H402*

H502*

--

--

--

--

2

2

2

3

3

--

--

--

--

2

2

2

3

3

--

--

3

3 H502*

H602*

--

--

--

--

2

2

2

3

3

--

--

--

--

2

2

2

3

3

--

-- ---

3 H602*

H702*

--

--

--

--

--

--

--

3

3

--

--

--

--

--

--

--

3

3

--

--

--

-- H702*

H802*

--

--

--

--

--

--

--

3

3

--

--

--

--

--

--

--

3

3

--

--

--

-- H802*

High

Efficiency

Gas Heat

Section

G150

1

1

1

1

2

2

2

--

--

1

1

1

1

2

2

2

--

--

2

2

3

3

G150

G225

1

1

1

1

2

2

2

3

3

1

1

1

1

2

2

2

3

3

2

2

3

3

G225

G300

--

1

1

1

2

2

2

3

3

--

--

1

1

2

2

2

3

3

2

2

3

3

G300

G302* --

1

1

1

2

2

2

3

3

--

--

1

1

2

2

2

3

3

2

2

3

3 G302*

G372* --

--

--

--

2

2

2

3

3

--

--

--

--

2

2

2

3

3

--

2

3

3 G372*

G452* --

--

--

--

2

2

2

3

3

--

--

--

--

2

2

2

3

3

--

--

3

3 G452*

G525* --

--

--

--

--

--

--

3

3

--

--

--

--

--

--

--

3

3

--

--

--

-- G525*

G602* --

--

--

--

--

--

--

3

3

--

--

--

--

--

--

--

3

3

--

--

--

-- G602*

Electric

Heat

Section

E20

1

1

1

1

2

2

2

--

--

1

1

1

1

2

2

2

--

--

2

2

3

3

E20

E30

1

1

1

1

2

2

2

3

3

1

1

1

1

2

2

2

3

3

2

2

3

3

E30

E40

--

1

1

1

2

2

2

3

3

--

1

1

1

2

2

2

3

3

2

2

3

3

E40

E50

--

1

1

1

2

2

2

3

3

--

1

1

1

2

2

2

3

3

2

2

3

3

E50

E60

--

1

1

1

2

2

2

3

3

--

1

1

1

2

2

2

3

3

2

2

3

3

E60

E70

--

--

1

1

2

2

2

3

3

--

--

1

1

2

2

2

3

3

2

2

3

3

E70

E80

--

--

1

1

2

2

2

3

3

--

--

1

1

2

2

2

3

3

2

2

3

3

E80

E90

--

--

1

1

2

2

2

3

3

--

--

1

1

2

2

2

3

3

2

2

3

3

E90

E120

--

--

--

--

2

2

2

3

3

--

--

--

--

2

2

2

3

3

--

--

3

3

E120

* Gas heat sections with dual furnaces.

Wiring Diagram Option Identification

The Option Codes for these electrical options are shown on the wiring diagram.

Option Brief Description

Installed

A10

VFD Direct Drive Medium Static Plenum Fan

Factory

A10E

VFD Direct Drive High Static Plenum Fan

Factory

A11

Backward incline direct drive high static fan

Factory

AG71

2-stage On/Off Gas Control

Factory

AG72

4-stage On/Off Gas Control

Factory

AG73

Single Heat Section, 5:1 Modulation

Factory

AG74

Dual Heat Section, 10:1 Modulation

Factory

AK3

230/1 Supply Voltage

Factory

AK5

208/3 Supply Voltage

Factory

AK6

230/3 Supply Voltage

Factory

AK7

460/3 Supply Voltage

Factory

AK8

575/3 Supply Voltage

Factory

AR7

Open Bottom Return Air & Motorized 30% Outside

Horizontal Air Inlet

Factory

AR8

Horizontal 100% Outside Air with Motorized Damper

Factory

AR25

Modulating OA/RA Dampers requires Option GF control

Factory

AR2D 100% Outside Air Damper and Power Exhaust

Factory

AR2G Modulating OA/RA Dampers and gravity exhaust damper

(requires Option GF control)

Factory

AR2H Modulating OA/RA Dampers w/power exhaust (requires

Option GF control)

Factory

AR2L 100% Outside Air (no dampers) with Energy Recovery

including Power Exhaust

Factory

AR2M

Modulating OA/RA Dampers with Energy Recovery

including Power Exhaust (requires Option GF control)

Factory

AR2Y Two-position OA Damper with Gravity Exhaust

Factory

AUC8 Main Coil Hot Gas Bypass (fixed circuit only)

Factory

BA6

Unit Mounted disconnect on/off switch

Factory

BA7

Dual Mounted disconnect on/off switches

Factory

BC6

Convenience Outlet (requires separate power supply)

Fld&Fctry

BD5

Firestat, 200°F (field installed)

Field

BE8

DX Cooling Low Ambient Control (r/a only)

Factory

BE15

Space Mounted CO

2

Sensor

Field

BE17

Photoelectric Smoke Detector

Field