Poe temperature, Poe usage – Interlogix NS2503-24P/2C User Manual User Manual
Page 184
NS2503-24P/2C User Manual
184
poe temperature
Description:
Configure System PoE Temperature Threshold information
Command Level
Global Configuration
Syntax:
poe temperature
{ thershold } {0-100}
Parameters:
<0-100> Temperature Threshold: 0~100 C
Example:
Switch(config)# poe temperature threshold 60
Switch(config)# show poe
Maximum Available Power
POE Admin mode
Temperature Unit1
Temperature Unit2
Over Temperature
PoE Power Consumption
Temperature Threshold
Usage
Usage Threshold
PoE Power limit mode
:360Watts
:Enable
:34C/93F
:37C/98F
:Enable
: 0 Watts
:60
:0%
: 100%
: Consumption
poe usage
Description:
Configure System PoE Usage Threshold information
Command Level
Global Configuration
Syntax:
poe usage
{ thershold } {0-100}
Parameters:
<0-100> Usage Threshold: 0~100%
Example:
Switch(config)# poe usage threshold 10
Switch(config)# show poe
Maximum Available Power
POE Admin mode
Temperature Unit1
Temperature Unit2
Over Temperature
PoE Power Consumption
Temperature Threshold
Usage
Usage Threshold
PoE Power limit mode
:360Watts
:Enable
:34C/93F
:37C/98F
:Enable
: 0 Watts
:60
:0%
: 10%
: Consumption