184

poe temperature

Description:

Configure System PoE Temperature Threshold information

Command Level

Global Configuration

Syntax:

poe temperature

{ thershold } {0-100}

Parameters:

Thershold
<0-100> Temperature Threshold: 0~100 C


Example:

Switch(config)# poe temperature threshold 60

Switch(config)# show poe

Maximum Available Power
POE Admin mode
Temperature Unit1
Temperature Unit2
Over Temperature
PoE Power Consumption
Temperature Threshold
Usage
Usage Threshold
PoE Power limit mode

:360Watts
:Enable
:34C/93F
:37C/98F
:Enable
: 0 Watts
:60
:0%
: 100%
: Consumption

poe usage

Description:

Configure System PoE Usage Threshold information

Command Level

Global Configuration

Syntax:

poe usage

{ thershold } {0-100}

Parameters:

Thershold
<0-100> Usage Threshold: 0~100%

Example:

Switch(config)# poe usage threshold 10

Switch(config)# show poe

Maximum Available Power
POE Admin mode
Temperature Unit1
Temperature Unit2
Over Temperature
PoE Power Consumption
Temperature Threshold
Usage
Usage Threshold
PoE Power limit mode

:360Watts
:Enable
:34C/93F
:37C/98F
:Enable
: 0 Watts
:60
:0%
: 10%
: Consumption