beautypg.com

AERCO Innovation (G-14-2265 and above) User Manual

Page 94

background image

Innovation Water Heaters Installation, Operation & Maintenance Manual

CHAPTER 6 – MAINTENANCE

Page 94 of

206

AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, NY 10913

OMM-0078_0L

PRI: 11/25/2014

Phone: 800-526-0288

GF-128

LWCO Capacitor Electrical Short Test – Continued

2. Remove the Shell Harness Cable (male) connector from the P-5 (female) connector on the

rear panel of the C-More controller (see Figure 6-13).

Figure 6-13: Removing Shell Harness Cable from P5 Conn. on C-More Rear Panel

3. Using an ohmmeter, connect one ohmmeter probe to the LWCO capacitor terminal on the

unit shell as shown on left in Figure 6-14.

4. Connect the second ohmmeter probe to Pin #6 of Shell Harness Connector (removed

from the C-More controller) as shown on right in Figure 6-14.

Figure 6-14: Connecting Ohmmeter between LWCO Probe & Shell Harness Cable

Unplug Shell

Harness Cable

from

P5 Connector

Connect 1

st

Lead to LWCO

Connect 2

nd

Lead to PIN #6

19-Pin Shell Harness Cable

Connector

LWCO Probe Assembly

Ohmmeter