beautypg.com

AERCO Innovation (G-14-2265 and above) User Manual

Page 131

background image

Innovation Water Heaters Installation, Operation & Maintenance Manual

CHAPTER 8 – WATER HEATER MANAGEMENT

OMM-0078_0L

AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, NY 10913

Page 131 of

206

GF-128

Phone: 800-526-0288

PRI: 11/25/2014

NOTES:

1.

DO NOT PRESS AUTO-STROKE (RESET) BUTTON. DOING SO MAY ALTER ACTUATOR
CALIBRATION

2.

DEPRESS AND HOLD BRASS CLUTCH BUTTON TO MANUALLY ROTATE VALVE

Figure 8-6. Actuator PC Board Components

Power must be removed from the Actuator prior to attempting to disengage
the clutch. Failure to observe this precaution may damage the Actuator.

The PC board also contains a brass button which is used to disengage the clutch and permit the
ball valve to be manually rotated. To disengage the clutch, proceed as follows:

Actuator Clutch Disengagement

1.

Disconnect the 4-pin connector on the Actuator to ensure that 24 VAC power is not being
supplied

2.

Press and hold the brass CLUTCH button shown in Figure 8-6.

3.

With the CLUTCH button depressed, the ball valve can be manually rotated from the fully
open (90°) to the fully closed (0°) position.

CLUTCH
(See Note 2)

POTENTIOMETER

AUTO-STROKE (RESET) BUTTON
DO NOT PRESS
(See Note 1)

DIP SWITCHES (4)
1–OFF (DOWN)
2–OFF (DOWN)
3–ON (UP)
4–OFF (DOWN)

TERMINALS (5)