Innovation Water Heaters Installation, Operation & Maintenance Manual
CHAPTER 3 – OPERATION
OMM-0078_0L
AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, NY 10913
Page 43 of
206
GF-128
Phone: 800-526-0288
PRI: 11/25/2014
3.4 OPERATING MENU
The Operating Menu displays a number of key operating parameters for the unit, as listed in
Table 3-2. This menu is “Read-Only” and does not allow personnel to change or adjust any
displayed items. It can therefore be viewed at any time without entering a password. Pressing
the
▲ arrow key to display the menu items in the order listed (Top-Down). Pressing the ▼
arrow key will display the menu items in reverse order (Bottom-Up).
A full description of each item appears in Table A-1 of Appendix A – Innovation Menu Item
Descriptions.
Table 3-2: Operating Menu
Menu Item Display
Available Choices or Limits
Appears only if enabled
in the following menu:
Minimum
Maximum
1
Active Setpoint
40°F
190°F
2
Inlet Temp
30°F
240°F
Calibration Menu
3
Air Temp
-70°F
245°F
4
* Outdoor Temp
-70°F
130°F
Configuration Menu
5
Valve Position In
0%
100%
6
Exhaust Temp
40°F
560°F
7
Valve Position Out
0%
100%
Calibration Menu
8
FFWD Temp
30°F
240°F
Calibration Menu
9
Flame Strength
0%
100%
10
Oxygen Level
-32%
32%
11
Ignition Time
0.00
10.00
12
SSOV Time to OPN
0.00
10.00
13
Run Cycles
0
999,999,999
14
Run Hours
0
999,999,999
15
Fault Log
0
19
* NOTE
The Outdoor Temp display item shown with an asterisk in Table 3-2 will not
be displayed unless the Outdoor Sensor function has been enabled in the
Configuration Menu (Table 3-4).