Output type, Output type -3, 1 specifications – KEYENCE FS-N10 Series User Manual
Page 89: Sp eci fic at io ns, Digital fiber sensor fs-n10 series user's manual

5-1 Specifications
5
Sp
eci
fic
at
io
ns
5-3
- Digital Fiber Sensor FS-N10 Series User's Manual -
*1
For M8 connector type, cable length must be 30 m or less.
*2
Increased by 100 mW (4.0 mA) for HIGH SPEED mode.
*3
One or two units connected: -20 to +55 °C; 3 to 10 units connected: -20 to +50 °C,
11 to 16 units connected: -20 to +45 °C. When using 2-output type, one unit is counted as two units.
All temperature specifications are for when the unit is mounted on a DIN rail; and installed on metal frame.
2-Output Type
Type
2-Output Type
Input/Output configuration
Cable
M8 connector
*1
Main unit/Expansion Units
Main unit
Expansion unit
Main unit
Expansion unit
Models
NPN
FS-N13N
FS-N14N
-
-
PNP
FS-N13P
FS-N14P
FS-N13CP
FS-N14CP
Number of
input/out-
put
Control output 2-output
2-output
2-output
2-output
Monitor output
(1-5V)
-
-
-
-
External input
1-input
1-input
-
-
Light source LED
Red 4-element LED (Wavelength: 630 nm)
Response time
50us(HIGH SPEED)/250us(FINE)/500us(TURBO)/1ms(SUPER)/4ms(ULTRA)/16ms(MEGA)
Output toggle
Light-ON/Dark-ON toggle
Timer functions
Timer OFF/OFF delay/ON delay/One-shot
Input/Out-
put specifi-
cations
Control output
(NPN)
NPN open collector 24 V or less, 2-output maximum 100 mA or less (used stand-alone)/20 mA or
less (multiple connections)
Residual voltage: 1V or less
Control output
(PNP)
PNP open collector 24 V or less, 2-output maximum 100 mA or less (used stand-alone)/20 mA or
less (multiple connections)
Residual voltage: 1V or less
External input
Input time: 2 ms(ON) / 20 ms(OFF) or more. 25 ms(ON/OFF) or more only when toggled to
external calibration input
Expansion units
Up to 16 units can be connected (total connection of 17 units including the main unit); 2-output
type is treated as 2 units, however.
Protection circuit
Protection against reverse power connection, output overcurrent and output surge
Number of interference preven-
tion units
Up to 16 units can be connected, but may differ depending on the power mode.
0 for HIGH SPEED; 4 for FINE and 8 for TURBO/SUPER/ULTRA/MEGA
(These numbers double when "Double" is selected.)
Rating
Supply voltage
DC12-24V±10%, ripple (P-P) 10% or less
Power consumption
(NPN output type)
Normal: 900 mW or less (36 mA or less at 24 VDC; 48 mA or less at 12 VDC)
*2
ECO ON (All): 800 mW or less (32 mA or less at 24 VDC; 39 mA or less at 12 VDC)
*2
ECO Full: 470 mW or less (19 mA or less at 24 VDC; 23 mA or less at 12 VDC)
Power consumption
(PNP output type)
Normal: 1050 mW or less (42mA or less at 24 VDC; 56mA or less at 12 VDC)
*2
ECO ON (All): 950 mW or less (38mA or less at 24 VDC; 47mA or less at 12 VDC)
*2
ECO Full: 600 mW or less (24mA or less at 24 VDC; 29mA or less at 12 VDC)
Environ-
ment resis-
tance
Operating ambient
luminance
Incandescent lamp: 20,000 lx or less; solar light: 30,000 lx or less
Operating ambient
temperature
-20 °C to +55 °C (no freezing)
*3
Operating ambient
humidity
35 to 85% (no condensation)
Vibration resistance
10 to 55 Hz Compound amplitude 1.5 mm, two hours for each of X, Y and Z axes
Shock resistance
500m/s
2
, 3 times for each of X, Y and Z axes
Case material
Both main unit and cover material: Polycarbonate
Case dimensions
H30.3mm×W9.8mm×L71.8mm
Mass
Approx. 80g
Approx. 70g
Approx. 22g
Approx. 22g