External input, External input -17, External – KEYENCE FS-N10 Series User Manual
Page 63: Input
4-3
Detection Settings (Func)
4
Set
tings
for Ad
v
an
c
ed Fu
nct
ion
s
4-17
- Digital Fiber Sensor FS-N10 Series User's Manual -
On sensor amplifiers with an external input option (FS-N11C
/N12C
/N11EN
/
N12EN
/N13
/N14
), the external input line can be controlled to utilize the
following functions:
*1 When the preset input is selected, the zero shift function is disabled and cannot be set.
*2 When the zero shift input is selected, each preset function is disabled and cannot
be set.
• For external input cabling, see
"Wiring Diagrams for Sensor Amplifiers"
• Provide a short-circuit time of 2 ms or more, and 25 ms or more when
external calibration input is selected.
External Input
Refer to page 4-2 "Detection Settings (Func)" for setting methods.
Display
Function
oFF
Disables use of the external input function. (Default)
SEt
External calibration input
Uses the external input to perform calibration.
PrSt
*1
Preset input
Executes a preset at the rising edge of the external input.
ShFt
*2
Zero shift input
Executes a zero shift at the rising edge of the external input.
"Setting the Current Received Light Intensity to 0 (Zero Shift)"
rSt
Reset input
Resets the display at the rising edge of the external input when using
the hold function, limit setting detection, or counter output mode.
"Light intensity hold display" (page 4-25), "Excess gain hold (%)
"Limit setting output mode" (page 4-36)
LoFF
Transmission OFF input
Keeps the transmission off during signal input.
PAUS
Pause function
Locks the output condition during external input.
SLEP
Sleep function
Uses the power save mode during external input.
Reference