3 list of recipe function settings, List of recipe function settings -7, List of recipe function settings – KEYENCE FS-N10 Series User Manual
Page 105: App endi x, D-on, Shot, On-d, Setp, 101p, Limt
App
endi
x
6-7
- Digital Fiber Sensor FS-N10 Series User's Manual -
6
6-3
List of Recipe Function Settings
Refer to
"Selecting Recipe" (page 3-19) for details on selecting recipes.
The following details are set using the recipe function.
Application item
Setting item
Setting
Reference
page
Fall detection
(
r-1 FALL
)
Output condition
no
N.O. (1-ch)
d-on
D-on (2-ch)
Output timer
Shot
One shot (1-ch)
on-d
ON delay (2-ch)
Detection mode
~L_d
Falling edge detection mode
Sub display
HLd
Hold display
Setting value
20
20 (1-ch)
-
300
300 (2-ch)
-
Percentage calibration
(
r-2 SEtP
)
Output condition
d-on
D-on
Sensitivity setting
SEtP
Percentage calibration
Target percentage value
-5P
-5%
Preset saturation level
101P
101%
External input
SEt
External calibration input
Output2 detection mode
LiMt
Limit setting detection mode
Limit setting value
100
100
Reflective background
cancellation*
1
(
r-3 0SEt
)
Sensitivity setting
0SEt
Zero shift calibration
External input
ShFt
Zero shift input
Full light intensity*
1
(
r-4 MEGA
)
Sensitivity setting
0SEt
Zero shift calibration
External input
ShFt
Zero shift input
Power mode
MEGA
MEGA mode
Display gain
FuLL
Full
Sub display
StdE
Extension display
Area detection*
2
(
r-5 ArEA
)
Detection mode
ArEA
Area detection mode
Sensitivity setting
SEtP
Percentage calibration
Percentage target value
-10P
-10%
0-datum*
2
(
r-6 0dtm
)
Output condition
d-on
D-on
Detection mode
dtM2
DATUM2 mode
Sensitivity setting
SEtP
Percentage calibration
Percentage target value
-5P
-5%
External input
SEt
External calibration input
Sub display
StdE
Extension display
Output2 detection mode
LiMt
Limit setting output
Limit setting value
100
100
Reference