The analog output can be automatically scaled so that the 5 V is output in respect to
the received light intensity "
100.0
". This function is used simultaneously with the
various preset function. This function is useful when frequently using the preset
function as the analog output can be constantly sequenced with the "
.0
to
100.0
"
display, etc.
* Not available for the FS-N10 Series shipped before March 10, 2011.
1
When received light intensity is dis-
played, press and hold the [MODE] but-
ton, [SET] and
button
simultaneously for 3 seconds or more.
ProG YES
or
ProG no
is displayed.
2
Press the [MODE] button once.
3
Using the
button, select
Pr-A
Std
to not change the analog upper limit
value when the preset function is exe-
cuted, and select
Pr-A PrSt
to change
the analog upper limit value sequen-
tially when the preset function is exe-
cuted. Then, hold down the [MODE] button.
When "
Std
" (default) is set, the analog output upper limit will not change
even if the various preset function is used.
Analog scaling mode (FS-N11MN only)