Display gain, Display gain -32 – KEYENCE FS-N10 Series User Manual
Page 78

4-5 System Settings (SYS)
4
Set
tings
f
o
r
Ad
v
an
ced F
u
nct
ion
s
4-32
- Digital Fiber Sensor FS-N10 Series User's Manual -
Received light intensity can be increased 4 times without sacrificing response time.
The maximum received light intensity value which can be displayed differs according
to the power mode setting and display screen.
The maximum received light intensity values which can be displayed are shown
below.
"Extension display" (page 4-24)
• This function is not supported in the
hSP
(HIGH SPEED) mode and
the light intensity expansion setting screen is not displayed.
• When the preset function is used in DATUM1 or DATUM2 mode,
correctible values are limited to 200.
Display Gain
Refer to page 4-2 "System Settings (SYS)" for setting methods.
Display
Function
Std
(Standard)
Normal light intensity display (Default)
FuLL
(Full)
Full light intensity display (Hysteresis increases 4 times)
Display
screen
Display
gain
HIGH
SPEED
FINE
TURBO SUPER
ULTRA
MEGA
Normal dis-
play
Std
4095
4095
4095
8190
9999
9999
FuLL
-
9999
9999
9999
9999
9999
StdE
(Extension
display)
Std
4095
4095
4095
8190
32760
65504
FuLL
-
16380
16380
32760
65504
65408
Point