beautypg.com

Chassis alarms – Cisco 12000/10700 V3.1.1 User Manual

Page 551

background image

18-3

Cisco 12000/10700 v3.1.1 Router Manager User Guide

OL-4455-01

Chapter 18 Fault Management

Cisco 12000/10720 Router Trap Support

Informational

Normal

Chassis Alarms

Table 18-2

provides information on traps that result in alarms raised against the chassis object.

Table 18-2 Monitored Attributes for a GRP Module

Trap

Alarm Description

Severity

Clears

Cold start

Cold Start: Agent reinitializing; configuration
may have changed.

Major

Cold start

RPR+ Switchover

RPR+ Cold Start: Agent reinitializing;
configuration may have changed

Major

RPR+ Switchover

RPR Switchover

RPR Cold Start: Agent
reinitializing;configuration may have changed

Major

RPR Switchover

Redundancy Framework (RF)
Progression

RF Notification: RF state has changed. Active
Unit: State: . Peer Unit:
State:

Major

Redundancy
Framework (RF)
Progression

Warm start

Warm Start: Agent reinitializing; configuration
is unaltered.

Major

Warm start

Authentication Failure

Authentication Failure

Major

Authentication
Failure

Voltage Normal

Voltage higher Chassis, normal, mV

Normal

Normal, Critical,
Shutdown, Warning,
NotPresent

Voltage Warning

Voltage higher Chassis, warning, mV

Warning

Critical, Shutdown,
Warning, NotPresent

Voltage Critical

Voltage higher Chassis, critical, mV

Critical

Critical, Shutdown,
Warning, NotPresent

Voltage Shutdown

Voltage higher Chassis, shutdown, mV Critical

Critical, Shutdown,
Warning, NotPresent

Voltage Not Present

Voltage higher Chassis, notPresent, mV Informational

Critical, Shutdown,
Warning, NotPresent

Temperature Normal

Slot : Switch Fabric Card Hot Sensor,
normal, degree celsius

Normal

Normal, Critical,
Shutdown, Warning,
NotPresent

Temperature Warning

Slot : Switch Fabric Card Hot Sensor,
warning, degree celsius

Warning

Critical, Shutdown,
Warning, NotPresent

Temperature Critical

Slot : Switch Fabric Card Hot Sensor,
critical, degree celsius

Critical

Critical, Shutdown,
Warning, NotPresent

Temperature Shutdown

Slot : Switch Fabric Card Hot Sensor,
shutdown, degree celsius

Critical

Critical, Shutdown,
Warning, NotPresent

Temperature Not Present

Slot : Switch Fabric Card Hot Sensor,
notPresent, degree celsius

Informational

Critical, Shutdown,