Chassis alarms – Cisco 12000/10700 V3.1.1 User Manual
Page 551
18-3
Cisco 12000/10700 v3.1.1 Router Manager User Guide
OL-4455-01
Chapter 18 Fault Management
Cisco 12000/10720 Router Trap Support
•
Informational
•
Normal
Chassis Alarms
provides information on traps that result in alarms raised against the chassis object.
Table 18-2 Monitored Attributes for a GRP Module
Trap
Alarm Description
Severity
Clears
Cold start
Cold Start: Agent reinitializing; configuration
may have changed.
Major
Cold start
RPR+ Switchover
RPR+ Cold Start: Agent reinitializing;
configuration may have changed
Major
RPR+ Switchover
RPR Switchover
RPR Cold Start: Agent
reinitializing;configuration may have changed
Major
RPR Switchover
Redundancy Framework (RF)
Progression
RF Notification: RF state has changed. Active
Unit:
Major
Redundancy
Framework (RF)
Progression
Warm start
Warm Start: Agent reinitializing; configuration
is unaltered.
Major
Warm start
Authentication Failure
Authentication Failure
Major
Authentication
Failure
Voltage Normal
Voltage higher Chassis, normal,
Normal
Normal, Critical,
Shutdown, Warning,
NotPresent
Voltage Warning
Voltage higher Chassis, warning,
Warning
Critical, Shutdown,
Warning, NotPresent
Voltage Critical
Voltage higher Chassis, critical,
Critical
Critical, Shutdown,
Warning, NotPresent
Voltage Shutdown
Voltage higher Chassis, shutdown,
Critical, Shutdown,
Warning, NotPresent
Voltage Not Present
Voltage higher Chassis, notPresent,
Critical, Shutdown,
Warning, NotPresent
Temperature Normal
Slot
normal,
Normal
Normal, Critical,
Shutdown, Warning,
NotPresent
Temperature Warning
Slot
warning,
Warning
Critical, Shutdown,
Warning, NotPresent
Temperature Critical
Slot
critical,
Critical
Critical, Shutdown,
Warning, NotPresent
Temperature Shutdown
Slot
shutdown,
Critical
Critical, Shutdown,
Warning, NotPresent
Temperature Not Present
Slot
notPresent,
Informational
Critical, Shutdown,
Warning, NotPresent