Checkline FH Series User Manual
Page 63

© ElektroPhysik MiniTest 7200 FH / MiniTest 7400 FH
63
Risk of injury
Within a distance of 15 cm, the sensor creates static magnetic fields of
up to 1 mTesla Keep a safety distance of at least 15 cm in order to avoid
injury through metallic parts being attracted by the sensor
Risk of injury through metallic splinters
The magnetic field may attract metal parts damaging the hard metal
sensor tip. Through the impact, the hard metal housing of sensor might
go into splinters.
Storage batteries and accessories
Make sure to use only original accessories and batteries
supplied/recommended by the manufacturer of gauge. Connect only to
compatible peripheral devices.
Connecting other devices
If you connect the gauge to another device as recommended by the
manufacturer, please refer to the corresponding instruction manual for
detailed information on safety issues. Do only connect original
accessories recommended by the manufacturer of the MiniTest 7200 FH
/ 7400 FH.
Keep away from water
The measuring unit is not waterproof. Keep in a dry place.
Keep away from explosion-hazardous area
Approved after-sales service
The gauge may only be repaired by approved and qualified after-sales
service personnel.
Medical facilities
Please ask for permission before using the gauge in medical facilities.