S-5500 SSG and Captured Corner Mullion Installation Instructions

Section IX: Vertical Splice Joints

Installation for Captured System





STEP #9 APPLY EXTERIOR CORNER COVER SPLICE

A. Apply .062 x .375 foam tape with pressure sensitive adhesive on both sides to the

cover splice as shown below.

B. Apply bond breaker tape to the splice (optional) if the joints of the covers are to be

sealed.

C. Apply sealant to the splice between the rows of tape to permanently adhere the

splice to the cover.

D. Press the splice firmly to apply it to the bottom of the upper cover.

COVER SPLICE

BOND BREAKER

TAPE

UPPER COVER

LOWER COVER

The covers are

notched to clear

the splice.