beautypg.com

EFCO S5500 SSG Captured User Manual

Page 28

background image


EFCO CORPORATION 6/2012

PART NO. Y556

Page 28 of 81

S-5500 SSG and Captured Corner Mullion Installation Instructions

Section V: Glazing Preparation (Captured)








Apply two beads of sealant in the

reglets of the corner mullion where

the corner mullion glazing adapter

mates into the corner mullion.

INTERMEDIATE HORIZONTAL

AT CAPTURED CORNER

Note: The corner mullion glazing adapter

must be set immediately after this step

before the sealant begins to cure.

CORNER

MULLIONS

CAPTURED

INTERMEDIATE

HORIZONTAL