beautypg.com

EFCO S5500 SSG Captured User Manual

Page 63

background image


EFCO CORPORATION 6/2012

PART NO. Y556

Page 63 of 81

S-5500 SSG and Captured Corner Mullion Installation Instructions

Section IX: Vertical Splice Joints

Installation for Captured System




STEP #8 SEAL PRESSSURE PLATES

A. Apply backer rod into the joint between the ends of the pressure plates at the splice joint to

backup the sealant applied in step 8-B.

B. Apply sealant into the joint ensuring to thoroughly wet the ends of the pressure plates. Apply

enough sealant to provide a minimum of 1/4” sealant contact surface on the ends of the

pressure plates.

GLAZING INFILL

Apply backer rod into joint

and seal water tight.

2-PIECE CORNER

MULLION ASSEMBLY