beautypg.com

EFCO S5500 SSG Captured User Manual

Page 34

background image


EFCO CORPORATION 6/2012

PART NO. Y556

Page 34 of 81

S-5500 SSG and Captured Corner Mullion Installation Instructions

Section V: Glazing Preparation (Captured)




INTERMEDIATE HORIZONTAL AT CAPTURED CORNER

Tool the sealant smooth

across the surface of the

joint plugs and on the

adapter.

JOINT

PLUG

JOINT

PLUG

CORNER

MULLIONS

CORNER MULLION

ADAPTER

STEP #4 INSTALL ADAPTERS AND PRESET GASKETS

Install the glazing adapters and preset gaskets as required for the outside glazed or

inside glazed system. Install glazing as required. Refer to “Section VIII: Glazing
Preparation” and “Section IX Glazing Installation” beginning on page 44 of the Series

5500 Outside Glazed Installation Instructions, or page 49 of the Series 5500 Inside

Glazed Installation Instructions.

CAPTURED

INTERMEDIATE

HORIZONTAL