Environmental and power requirements
This section provides environmental and power specifications for the stand-up and mezzanine
HBAs.
Stand-up HBAs
The following table provides environmental and power specifications for the stand-up HBAs.
Mezzanine HBAs
The Brocade 804 mezzanine adapter conforms to environmental and power specifications for the
supported blade servers and blade system enclosures where they install. Refer to the
documentation provided for these products for information. Also refer to
system enclosures (mezzanine adapters)”
Fibre Channel standards compliance
Brocade adapters meet or exceed the Fibre Channel standards for compliance, performance, and
feature capabilities as defined in the Brocade standards compliance list. This information is
available through links under the Solutions and Technology heading on the Brocade website at
.
Regulatory compliance
This section provides international regulatory compliance notices for the Brocade adapters.
Stand-up adapters
The regulatory statements in this section pertain to the following stand-up adapters:
•
415 HBA
TABLE 29
Environmental and power requirements
Property
Requirement
Airflow
None required.
Operating Temperature (dry bulb)
0°C to 55°C (32°F to 131°F)
Operating Humidity
5% to 93%
(relative-noncondensing)
Nonoperating Temperature
-43°C to 73°C (-40°F to 163°F)
(dry bulb)
Nonoperating Humidity
5% to 95%
(relative-noncondensing)
Power Dissipation
6.3W
Maximum not including SFP.
Operating Voltage
Per PCIe 2.0 specifications