; PRECAT BANK SLOW/FAST DYNAMICS FAST THRESHOLD ***
; Set FAST/HIGH Threshold.
;
; Min Val Max Val
; 0.000 -> 1.000 (default) (in Volts)
7165.1=1.00
;/*$PAGE*/
; *************** PRECAT RIGHT BANK ***************
; PRECAT BANK ENABLE ******************************
; 0 DISABLED (default)
; 1 ENABLED
7100.2=0
; PRECAT BANK OXYGEN SENSOR FAULT ACTION **********
; Select Valve Output when Oxygen Sensor faults.
;
; 0 Output Fault Percent (default)
; 1 Output Opposite Bank Valve Percent
; 2 MAP Programming Table Percent (if MAP sensors ENABLED)
7113.2=0
; PRECAT VALVE MANUAL OUTPUT **********************
; Set Starting Valve Output.
; Output valid when Bank ENABLED and at Run RPM
; and in AFC MANUAL Mode.
;
; Min Val Max Val
; 0.0 (default) -> 100.0 (in valve opening %)
7184.2=0.0
; PRECAT VALVE START OUTPUT **********************
; Set Starting Valve Output.
; Output valid when Bank ENABLED and at Run RPM
; and in AFC AUTO Mode.
;
; Min Val Max Val
; 0.0 (default) -> 100.0 (in valve opening %)
7185.2=0.0
; PRECAT VALVE FAULT OUTPUT **********************
; Set Starting Valve Output.
; Output valid when Bank ENABLED and at Run RPM
; and in AFC AUTO Mode and Oxygen Sensor faulted
; and Sensor Fault Action set to Fault Percent.
;
; Min Val Max Val
; 0.0 (default) -> 100.0 (in valve opening %)
7186.2=0.0
;