beautypg.com

Dynalco AF-900PC Air/Fuel Ratio Controller User Manual

Page 11

background image

10

Terminal Strip

TS1

Top Row

Description

TS1-10
TS1-11
TS1-12
TS1-13
TS1-14
TS1-15
TS1-16
TS1-17
TS1-18

Pre-Catalyst Thermocouple + (Yellow)
Pre-Catalyst Thermocouple - (Red)
Post-Catalyst Thermocouple + (Yellow)
Post-Catalyst Thermocouple - (Red)
Left Exhaust Thermocouple + (Yellow)
Left Exhaust Thermocouple - (Red)
Right Exhaust Thermocouple + (Yellow) (DB only)
Right Exhaust Thermocouple - (Red) (DB only)
Not Used

Terminal Strip

TS2

Bottom Row

Description

TS2-1
TS2-2
TS2-3
TS2-4
TS2-5
TS2-6
TS2-7
TS2-8
TS2-9
TS2-10

TS2-11
TS2-12

Not Used
+8 VDC Pickup Power for Active Speed Pickup (Optional)
Left & Right Bank Valve Power Common
Left Manifold Air Temperature (MAT) Thermocouple + (Yellow) (Optional)
Left Manifold Air Temperature (MAT) Thermocouple - (Red) (Optional)
Right Manifold Air Temperature (MAT) Thermocouple + (Yellow) (Optional)
Right Manifold Air Temperature (MAT) Thermocouple - (Red) (Optional)
Left Manifold Air Pressure (MAP) Sensor Input (+)
Left Manifold Air Pressure (MAP) Sensor Input (-)
DC Power for Left and Right Manifold Air Pressure (MAP) Sensors
(Factory set to Input Supply Voltage but jumper selectable to 5.0 VDC)
Right Manifold Air Pressure (MAP) Sensor Input (+)
Right Manifold Air Pressure (MAP) Sensor Input (-)

Terminal Strip TS2, Top Row
No Connections Currently Used

Terminal Strip

TS3

Bottom Row

Description

TS3-1
TS3-2
TS3-3
TS3-4
TS3-5
TS3-6
TS3-7
TS3-8
TS3-9

Left Bank + PWM Valve Position Control
Left Bank Valve +12/24 DC Power
Right Bank + PWM Valve Position Control
Right Bank Valve +12/24 DC Power / Right Bank Oxygen Sensor Heater -
Left & Right Bank Oxygen Sensor Heater -
Left & Right Bank Oxygen Sensor Heater +
Not Used
+10 to 30 VDC System Power In @ 70 Watts (#16 AWG wire required)
DC Power Common (#16 AWG wire required)