Dynalco AF-900PC Air/Fuel Ratio Controller User Manual
Page 73
![background image](/manuals/601358/73/background.png)
72
; *************** TRIP CHANNEL #14 ****************
; PRECAT LEFT BANK VALVE HIGH LIMITED
; Fault on PreCat Valve stuck at maximum opening.
; TRIP MODE ***************************************
; Select TRIP Relay to activate on channel fault.
;
; 0 DISABLED (default)
; 1 ALARM RELAY
; 2 SHUTDOWN RELAY
; 3 AUX RELAY
600.14=0
; TRIP LOG ENABLE *********************************
; Trigger asynchronous LOG on channel fault.
;
; 0 DISABLED (default)
; 1 ENABLED
601.14=0
;/*$PAGE*/
; *************** TRIP CHANNEL #15 ****************
; PRECAT RIGHT BANK OXYGEN SENSOR FAULT ***********
; Fault on bad sensor OR sensor NOT detected.
; NOT applicable if sensor channel DISABLED.
; TRIP MODE ***************************************
; Select TRIP Relay to activate on channel fault.
;
; 0 DISABLED (default)
; 1 ALARM RELAY
; 2 SHUTDOWN RELAY
; 3 AUX RELAY
600.15=0
; TRIP LOG ENABLE *********************************
; Trigger asynchronous LOG on channel fault.
;
; 0 DISABLED (default)
; 1 ENABLED
601.15=0
; *************** TRIP CHANNEL #16 ****************
; PRECAT RIGHT BANK OXYGEN SENSOR HEALTH **********
; Fault on low sensor health.
; See OXYGEN SENSOR HEALTH section.
; TRIP MODE ***************************************
; Select TRIP Relay to activate on channel fault.
;
; 0 DISABLED (default)
; 1 ALARM RELAY
; 2 SHUTDOWN RELAY
; 3 AUX RELAY
600.16=0