Dynalco AF-900PC Air/Fuel Ratio Controller User Manual
Page 70
69
; *************** TRIP CHANNEL #08 ****************
; PRECAT LEFT BANK OXYGEN SENSOR HEALTH **********
; Fault on low sensor health.
; See OXYGEN SENSOR HEALTH section.
; TRIP MODE ***************************************
; Select TRIP Relay to activate on channel fault.
;
; 0 DISABLED (default)
; 1 ALARM RELAY
; 2 SHUTDOWN RELAY
; 3 AUX RELAY
600.8=0
; TRIP LOG ENABLE *********************************
; Trigger asynchronous LOG on channel fault.
;
; 0 DISABLED (default)
; 1 ENABLED
601.8=0
; *************** TRIP CHANNEL #09 ****************
; PRECAT LEFT BANK EXHAUST TEMPERATURE SENSOR FAULT
; Fault on bad sensor OR sensor NOT detected.
; NOT applicable if sensor channel DISABLED.
; TRIP MODE ***************************************
; Select TRIP Relay to activate on channel fault.
;
; 0 DISABLED (default)
; 1 ALARM RELAY
; 2 SHUTDOWN RELAY
; 3 AUX RELAY
600.9=0
; TRIP LOG ENABLE *********************************
; Trigger asynchronous LOG on channel fault.
;
; 0 DISABLED (default)
; 1 ENABLED
601.9=0
;