beautypg.com

Appendix a – Dynalco AF-900PC Air/Fuel Ratio Controller User Manual

Page 53

background image

21.

APPENDIX A.

lExample of a Configuration File (AF900PC.SPC)

; Filename : AF900PC.SPC
; Date : 2002/03/11
;*****************************************************************************
; (1) This template download file is used to configure a Dynalco AF900PC.
; Copies of this file may be downloaded from the Dynalco Controls website
; (www.dynalco.com).
; (2) Desired configuration values should be entered in all appropriate
; fields before downloading to the AF900PC. The default value for
; each configuration variable is set as the initial download value.
; (3) Comments are included for each configuration variable to explain the
; purpose and programmable values associated with each variable.
;**************************************************
; *************************************************
; ******************* PASSWORD ********************
; *************************************************

; SETUP PASSWORD **********************************
; Selects the password for entering front-
; panel AF900PC SETUP Mode.
;
; The password may be up to eight (8)
; characters in length. The password must
; contain ONLY the digit characters '1',
; '2', '3', or '4'. If any other characters
; are used, no user will be able to enter
; front-panel AF900PC SETUP Mode.
;
; This password is ONLY required to
; configure the AF900PC through the
; front-panel. NO password is required
; to download a configuration file to
; the AF900PC.
6112.0=1234

; SETUP PASSWORD ACTIVE TIME **********************
; Selects the active time for the front-
; panel SETUP Password. This is the time
; that the password remains active AFTER
; a user has exited front-panel AF900PC
; SETUP Mode. This allows a user to re-
; enter SETUP Mode WITHOUT having to re-
; enter the password.
;
; Min Val Max Val
; 30 -> 60 (default) -> 300 (in seconds)
6101=60