Dynalco AF-900PC Air/Fuel Ratio Controller User Manual

Page 52

background image

51

Left Bank Pre-Catalyst Output Low
Param #7241.1

The left bank pre-catalyst control output is at its low
limit.

Left Bank Pre-Catalyst Output High
Param #7243

The left bank pre-catalyst control output is at its
minimum limit

Right Bank Pre-Catalyst O

2

Sensor Fault

Param #7232.2

Sensor reading is outside normal range of 0 – 1V

Right Bank Pre-Catalyst O

2

Sensor Health

Param #950.2

Sensor health is degraded – time to replace

Right Bank Pre-Catalyst Thermocouple
Fault Param #7233.2

Thermocouple open or reading is outside valid range

Right Bank Pre-Catalyst Temperature Low
Param #7120.2

Temperature before the catalytic converter on right
bank is too low


Right Bank Pre-Catalyst Output Low
Param #7241.2


The right bank pre-catalyst control output is at its low
limit


Right Bank Pre-Catalyst Output High
Param #7243.2


The right bank pre-catalyst control output is at its
minimum limit


Pre-Catalyst Thermocouple Fault
Param #7265


Thermocouple open or reading is outside valid range

Pre- Catalyst Temperature Low
Param #7251

Temperature after the catalytic converter is too low

Left Bank Intake Manifold Temperature
Sensor Fault, Param #7407.1

Left bank sensor reading is outside normal range of 4
– 20mA

Right Bank Intake Manifold Temperature
Sensor Fault, Param #7407.2

Right bank sensor reading is outside normal range of
4 – 20mA

Catalytic Converter Temperature
Difference Too Low, Param #7267

The temperature difference between the inlet and
outlet of the ctalytic converter is too small, indicating
that the catalyst is not working properly to reduce
emissions

Catalytic Converter Temperature
Difference Too High, Param #7268

The temperature difference between the inlet and
outlet of the catalytic converter is too large, indicating
something is wrong with the catalytic converter such
as it might be plugged.