Dynalco AF-900PC Air/Fuel Ratio Controller User Manual
Page 52
51
Left Bank Pre-Catalyst Output Low
Param #7241.1
The left bank pre-catalyst control output is at its low
limit.
Left Bank Pre-Catalyst Output High
Param #7243
The left bank pre-catalyst control output is at its
minimum limit
Right Bank Pre-Catalyst O
2
Sensor Fault
Param #7232.2
Sensor reading is outside normal range of 0 – 1V
Right Bank Pre-Catalyst O
2
Sensor Health
Param #950.2
Sensor health is degraded – time to replace
Right Bank Pre-Catalyst Thermocouple
Fault Param #7233.2
Thermocouple open or reading is outside valid range
Right Bank Pre-Catalyst Temperature Low
Param #7120.2
Temperature before the catalytic converter on right
bank is too low
Right Bank Pre-Catalyst Output Low
Param #7241.2
The right bank pre-catalyst control output is at its low
limit
Right Bank Pre-Catalyst Output High
Param #7243.2
The right bank pre-catalyst control output is at its
minimum limit
Pre-Catalyst Thermocouple Fault
Param #7265
Thermocouple open or reading is outside valid range
Pre- Catalyst Temperature Low
Param #7251
Temperature after the catalytic converter is too low
Left Bank Intake Manifold Temperature
Sensor Fault, Param #7407.1
Left bank sensor reading is outside normal range of 4
– 20mA
Right Bank Intake Manifold Temperature
Sensor Fault, Param #7407.2
Right bank sensor reading is outside normal range of
4 – 20mA
Catalytic Converter Temperature
Difference Too Low, Param #7267
The temperature difference between the inlet and
outlet of the ctalytic converter is too small, indicating
that the catalyst is not working properly to reduce
emissions
Catalytic Converter Temperature
Difference Too High, Param #7268
The temperature difference between the inlet and
outlet of the catalytic converter is too large, indicating
something is wrong with the catalytic converter such
as it might be plugged.