Components/installation summary – Dynalco AF-900PC Air/Fuel Ratio Controller User Manual
Page 7
6
5. Components/Installation Summary
5.1 System Components
Included
Single Bank Dual Bank
AF-900PC-3F
Air/Fuel
Ratio
Controller
(1)
(1)
400A-12959
Pre-Cat O2 Sensor Cable Ass’y (50 ft)
(1)
(2)
400A-12064
Post-Cat O2 Sensor Cable Ass’y (100 ft)
(1)
(1)
External Components (purchase separately)
Heated Pre-Cat Oxygen Sensor (Bosch p/n 15718)
(1)
(2)
Full-Authority
Fuel
Valve
(1)
(2)
Optional External Components (purchase separately)
M201
Magnetic Pickup for speed sensing
(1)
(1)
C101-XX
Pickup Cable for M201
(1)
(1)
Heated Post-Cat Oxygen Sensor (Bosch p/n 15718)
(1)
(1)
K
type
thermocouples
(ungrounded)
(2)
(2)
5.2 Installation Summary
1. Mount AF900PC Controller
2. Install Oxygen Sensor(s) in each engine exhaust bank
3. Run cables for Oxygen Sensors to controller (conduit must be used for Division 2
certification).
4. Install full-authority fuel valve(s)
5. Wire power to controller (10-30 VDC)
6. Install pickup for engine run signal and wire to controller. (Note: A contact closure run
signal may be used instead of the magnetic pickup).
7. Wire controller Alarm, Shutdown, and Auxiliary relay outputs to engine panel
shutdown and warning devices as required.