; Min Val Max Val
; 25 -> 50 (default) -> 9999 (in RPM)
151=50

; START RPM HYSTERESIS ****************************
; Start RPM hysteresis to re-enable RPM Tooth number
; changes once Start RPM is reached.
;
; Min Val Max Val
; 0 -> 25 (default) (in RPM)
;
; Example:
; If Start RPM = 50 RPM &
; Start Hyst = 20 RPM
; then RPM tooth changes DISABLED > 50 RPM
; but re-ENABLED < 30 RPM
; (50 - 20 = 30 RPM)
152=25

; START DELAY *************************************
; Delay, after Start RPM reached or Run Contacts
; CLOSED, before RUN state.
;
; Min Val Max Val
; 0 -> 30 (default) -> 300 (in seconds)
153=30

;