7
6. Installation Details
6.1 Mounting the AF900PC Controller
The AF900PC Controller (Fig. 1) should be mounted at “eye level” in an accessible
location for easy display and keypad interface. The controller must be mounted in
surroundings where vibration is minimal and the ambient temperature does not
exceed 80 Deg C. A typical mounting location is on the side of the engine control
panel. A shock mount kit should always be used while mounting. All wiring enters
the controller through the bottom of the enclosure. There are three holes for ½”
conduit entry. All wiring is connected to the main board using removable terminal
blocks for ease of wiring and controller replacement.
NOTE: Installation requires four mounting holes.
12.25
12.8
8.0
10.25
13.5
Front View
Inside View
AF900PC
Air/Fuel Ratio Control System
Fig. 1