; TRIP LOG ENABLE *********************************
; Trigger asynchronous LOG on channel fault.
;
; 0 DISABLED (default)
; 1 ENABLED
601.16=0
; *************** TRIP CHANNEL #17 ****************
; PRECAT RIGHT BANK EXHAUST TEMPERATURE SENSOR FAULT
; Fault on bad sensor OR sensor NOT detected.
; NOT applicable if sensor channel DISABLED.
; TRIP MODE ***************************************
; Select TRIP Relay to activate on channel fault.
;
; 0 DISABLED (default)
; 1 ALARM RELAY
; 2 SHUTDOWN RELAY
; 3 AUX RELAY
600.17=0
; TRIP LOG ENABLE *********************************
; Trigger asynchronous LOG on channel fault.
;
; 0 DISABLED (default)
; 1 ENABLED
601.17=0
;/*$PAGE*/
; *************** TRIP CHANNEL #18 ****************
; PRECAT RIGHT BANK EXHAUST TEMPERATURE LOW FAULT
; Fault on LOW PreCat Exhaust Temperature.
;
; Min Val Max Val
; 0 -> 575 (default) -> 2000 (in degrees F)
7211.2=575
; TRIP MODE ***************************************
; Select TRIP Relay to activate on channel fault.
;
; 0 DISABLED (default)
; 1 ALARM RELAY
; 2 SHUTDOWN RELAY
; 3 AUX RELAY
600.18=0
; TRIP LOG ENABLE *********************************
; Trigger asynchronous LOG on channel fault.
;
; 0 DISABLED (default)
; 1 ENABLED
601.18=0