Specifications – Dynalco AF-900PC Air/Fuel Ratio Controller User Manual
Page 6
5
4. Specifications
Inputs
Left Bank O
2
Sensor (heated)
Right Bank O
2
Sensor (heated)
RPM Input (Magnetic Pickup)
RPM Status (Contact Closure)
Controller
Outputs
Left Bank Output (PWM)
Right Bank Output (PWM)
Relay
Outputs
3 Relays, SPDT, rated @ 5A/24VDC, 1A/120VAC, and
0.5A/220VAC
Input Power
10 – 30 VDC @ 70 Watts Input Power to AF900PC controller
Sensor Power Out
+ 8 VDC Active Magnetic Pickup Sensor Power
Display
Backlit, 4 Line x 20 Character Alphanumeric Display with large
0.36” Characters
Data Logging
Internal 64M Flash Memory and Windows Based DynaTrend
Software to transfer the data to a laptop for viewing and graphing
Communications
Hardware: RS-232 / RS-485
Software: DynaHost Laptop Configuration
Modbus
Connections
All Two-Part Terminal Blocks
Operating Temperature
Range
- 30 to + 80 Deg C
Certification
CSA Class I, Division 2, Groups A, B, C, D