4. Specifications

Inputs

Left Bank O

2

Sensor (heated)

Right Bank O

2

Sensor (heated)

RPM Input (Magnetic Pickup)

RPM Status (Contact Closure)

Controller
Outputs

Left Bank Output (PWM)

Right Bank Output (PWM)

Relay
Outputs

3 Relays, SPDT, rated @ 5A/24VDC, 1A/120VAC, and
0.5A/220VAC

Input Power

10 – 30 VDC @ 70 Watts Input Power to AF900PC controller

Sensor Power Out

+ 8 VDC Active Magnetic Pickup Sensor Power

Display

Backlit, 4 Line x 20 Character Alphanumeric Display with large
0.36” Characters

Data Logging

Internal 64M Flash Memory and Windows Based DynaTrend
Software to transfer the data to a laptop for viewing and graphing

Communications

Hardware: RS-232 / RS-485

Software: DynaHost Laptop Configuration

Modbus

Connections

All Two-Part Terminal Blocks

Operating Temperature
Range

- 30 to + 80 Deg C

Certification

CSA Class I, Division 2, Groups A, B, C, D