Dynalco AF-900PC Air/Fuel Ratio Controller User Manual
Page 79
78
; TRIP MODE ***************************************
; Select TRIP Relay to activate on channel fault.
;
; 0 DISABLED (default)
; 1 ALARM RELAY
; 2 SHUTDOWN RELAY
; 3 AUX RELAY
600.26=0
; TRIP LOG ENABLE *********************************
; Trigger asynchronous LOG on channel fault.
;
; 0 DISABLED (default)
; 1 ENABLED
601.26=0
; *************** TRIP CHANNEL #27 ****************
; POSTCAT/PRECAT TEMPERATURE DELTA HIGH FAULT *****
; Fault if PostCat/PreCat Temperature difference
; greater than HIGH Delta threshold.
;
; Min Val Max Val
; 0 -> 2500 (default) (in degrees F)
7257=2500
; TRIP MODE ***************************************
; Select TRIP Relay to activate on channel fault.
;
; 0 DISABLED (default)
; 1 ALARM RELAY
; 2 SHUTDOWN RELAY
; 3 AUX RELAY
600.27=0
; TRIP LOG ENABLE *********************************
; Trigger asynchronous LOG on channel fault.
;
; 0 DISABLED (default)
; 1 ENABLED
601.27=0
;