; *************** TRIP CHANNEL #04 ****************
; POSTCAT TEMPERATURE LOW FAULT ******************
; Fault on LOW PostCat Temperature.
;
; Min Val Max Val
; 0 -> 600 (default) -> 2500 (in degrees F)
7026=600

; TRIP MODE ***************************************
; Select TRIP Relay to activate on channel fault.
;
; 0 DISABLED (default)
; 1 ALARM RELAY
; 2 SHUTDOWN RELAY
; 3 AUX RELAY
600.4=0

; TRIP LOG ENABLE *********************************
; Trigger asynchronous LOG on channel fault.
;
; 0 DISABLED (default)
; 1 ENABLED
601.4=0




; *************** TRIP CHANNEL #05 ****************
; POSTCAT TEMPERATURE HIGH FAULT ******************
; Fault on HIGH PostCat Temperature.
;
; Min Val Max Val
; 0 -> 2500 (default) (in degrees F)
7027=2500

; TRIP MODE ***************************************
; Select TRIP Relay to activate on channel fault.
;
; 0 DISABLED (default)
; 1 ALARM RELAY
; 2 SHUTDOWN RELAY
; 3 AUX RELAY
600.5=0

; TRIP LOG ENABLE *********************************
; Trigger asynchronous LOG on channel fault.
;
; 0 DISABLED (default)
; 1 ENABLED
601.5=0